Abstract

Background: Post-induction hypotension (PIH) is a common complication of general anaesthesia. Ultrasonographic assessment of inferior vena cava collapsibility index (IVCCI) and internal jugular vein (IJV) area changes may help predict its occurrence.    Aim: To compare the accuracy of IVCCI and IJV area change rate in predicting post-induction and severe post-induction hypotension.   Materials and Methods: This prospective clinical study included 100 adult patients aged 18–65 years with ASA physical status I–II undergoing elective surgery under general anaesthesia. Pre-induction ultrasonographic measurements of IVC diameter and IJV cross-sectional area were obtained. IVCCI and IJV area change rate were calculated. Haemodynamic parameters were monitored following induction, and diagnostic accuracy was assessed using receiver operating characteristic (ROC) analysis.  Results: Post-induction hypotension occurred in 73 (73%) patients, while severe hypotension occurred in 10 (10%) patients. IJV area change rate demonstrated the highest predictive accuracy for PIH, with an AUC of 0.80 (95% CI: 0.72–0.88), sensitivity of 78%, and specificity of 76% at a cut-off of >0.25. IVCCI showed an AUC of 0.76 (95% CI: 0.68–0.84), with sensitivity of 78% and specificity of 71% at a cut-off of >0.34. For severe PIH, IJV area change rate showed an AUC of 0.83, compared with 0.72 for IVCCI.  Conclusion: IJV area change rate demonstrated better predictive performance than IVCCI for post-induction and severe hypotension. Both ultrasonographic parameters may serve as useful non-invasive bedside tools for preoperative haemodynamic risk assessment.

Downloads

Published

2026-11-23

How to Cite

Kohli, V., Zafreen, S., Tyagi, V., & Rastogi, B. (2026). A Clinical Study: Comparison of Ultrasonographic Measures of Inferior Vena Cava Collapsibility Index and Change in Area of Internal Jugular Vein for Prediction of Hypotension During Induction of General Anaesthesia. Adolescência E Saúde, 1285–1290. https://doi.org/10.67440/ahj.vi.3651

Issue

Section

Original Articles